Air conditioning for small offices and studios

Hot afternoons cost you focus, and a row of screens or a busy meeting room makes it worse. We fit wall units, ceiling cassettes and multi-split systems in small offices, studios and practices across London and the Home Counties, with prices plus VAT and an install planned around your working day.

Small architecture studio in a Georgian townhouse with a white air conditioning unit high on the wall
commercial wall unit, from
£1,795 + VAT
ceiling cassette, from
£2,750 + VAT
TM44 inspection needed
Over 12 kW
and REFCOM certified
F-Gas

Wall units, cassettes or multi-split?

For a small office, the choice usually comes down to the ceiling, the room layout and where an outdoor unit can go.

SystemBest forNeedsWorth knowingFrom
Wall-mounted splitPrivate offices, meeting rooms, studiosWall space, ideally on an outside wallQuickest to fit. Air throws from one side, so a long room can have a warmer far end£1,795 + VAT
Ceiling cassetteOpen-plan rooms, receptions, larger studiosA suitable suspended ceiling with enough depth above itSpreads air four ways from the centre. Hard to fit into solid concrete ceilings£2,750 + VAT
Multi-splitSeveral small rooms with one outdoor positionA pipe route from each room to the outdoor unitEach room has its own control, but all rooms share one outdoor unitQuoted after survey
Separate single splitsRooms used at different times, or where cooling matters mostAn outdoor position for each systemOne fault doesn't stop the other roomsPriced per system

Business prices are plus VAT.

Sizing for people and equipment

An office gets hot from the inside as well as the outside. Each person gives off roughly 100 W of heat, and every desktop computer, screen, printer and coffee machine adds more. A meeting room full of people can need more cooling than a bigger office with two desks.

Glazing matters too. South and west-facing windows and top-floor rooms under a roof take far more heat in the afternoon. At the survey we count the people, the equipment and the windows, room by room, and size each unit from that.

Typical starting points

A guide for small offices. Your survey confirms the actual sizes.

SpaceTypical useStarting point
Private office, about 10–15 m²One or two peopleOne 2.5 kW wall unit
Meeting roomSix to eight people at a timeOne 3.5 kW unit
Studio, about 25–35 m²Four to six desksOne 5 kW unit, or two smaller ones
Open-plan floorEight or more desksCeiling cassettes or several wall units, after a survey

A server or comms cupboard needs its own dedicated cooling, because it runs day and night. Don't rely on office units that switch off in the evening.

Landlord consent and your lease

Most commercial leases need the landlord's written consent before you core through a wall or put an outdoor unit on the building. Landlords often set conditions on where units go, noise, working hours and whether you must remove everything when the lease ends.

We give you what landlords and managing agents usually ask for: spec sheets, outdoor unit noise figures, marked-up photos of the unit positions and pipe route, and a method statement. Planning rules for business premises differ from homes, and conservation areas and listed buildings need checks. Our planning guide covers the basics.

F-Gas leak checks for businesses

If your business controls the system, you're its operator under the F-Gas rules. That means you're responsible for making sure leak checks happen when the law requires them, and for keeping records. How often depends on how much refrigerant the system holds, measured in tonnes of CO2 equivalent.

5 tonnes CO2 equivalent is about 2.4 kg of R410A, or about 7.4 kg of R32. Most single wall units hold well under that, so they don't need a mandatory leak check. Larger multi-split systems, and older R410A systems, can be above it. We'll tell you which band your system is in and log every check.

  • Under 5 tonnes CO2 equivalent: no mandatory leak check
  • 5 to under 50 tonnes: at least every 12 months
  • 50 to under 500 tonnes: at least every 6 months
  • 500 tonnes or more: at least every 3 months, with automatic leak detection
  • Fitting automatic leak detection doubles the interval for systems under 500 tonnes

TM44 air conditioning inspections

If the air conditioning systems under your control add up to more than 12 kW of cooling, you need a TM44 inspection at least every 5 years. It's the combined total that counts: three 5 kW units make 15 kW.

An accredited energy assessor carries out the inspection and lodges the report on the national register. We're installers, not energy assessors, but we can give your assessor the system details they need and carry out any work the report recommends.

How an office install works

  1. Survey

    We check each room's heat load, the ceiling, the outdoor unit position, pipe routes and the electrics.

  2. Quote and documents

    You get a written quote plus VAT, and the documents your landlord or managing agent will ask for.

  3. Consent

    Once your landlord agrees in writing, we book the install.

  4. Install

    We plan the install around your working day. Talk to us about timing when you book, and we'll agree which rooms we work in and when.

  5. Commission and handover

    We pressure test, vacuum and commission the system, record the refrigerant as the F-Gas rules require, and show your team how to use the controls.

Office air conditioning prices

Business prices are plus VAT at 20%. Multi-split and larger systems are quoted after a survey.

  • Commercial wall unit

    Fitted in business hours

    from£1,795+ VAT
  • Ceiling cassette

    In a suitable suspended ceiling

    from£2,750+ VAT

Servicing for businesses

Office systems work harder than home ones, so they need servicing at least once a year, and twice for busy or heavily used spaces. LG asks for a service every six months to keep its warranty valid. A service keeps the units efficient, the air clean and the warranty in place.

Where your system needs an F-Gas leak check, we combine it with the service visit and give you a written record. Any F-Gas certified engineer can service the system and keep the manufacturer warranty valid, so you're never tied to us.

Office air conditioning questions

How much does office air conditioning cost?

A commercial wall unit starts from £1,795 + VAT, and a ceiling cassette in a suitable suspended ceiling from £2,750 + VAT. Multi-split systems and larger offices are quoted after a survey, because the price depends on the number of rooms and the pipe routes.

Can you install outside office hours?

We plan the install around your working day, so the team can keep working in the other rooms. Talk to us about timing when you book the survey and we'll agree a plan that suits you.

Do I need my landlord's permission?

Almost always. Most commercial leases need written consent for alterations, and air conditioning means a hole through an outside wall and a unit on the building. We give you the spec sheets, noise figures and a method statement to send with your request.

Does my office need a TM44 inspection?

Yes, if the air conditioning systems under your control add up to more than 12 kW of cooling. The inspection is needed at least every 5 years and is carried out by an accredited energy assessor. We can give the assessor your system details.

Does our system need F-Gas leak checks?

Only if it holds 5 tonnes CO2 equivalent of refrigerant or more. That's about 2.4 kg of R410A or 7.4 kg of R32. Most single wall units are below it. Above it, checks are needed at least every 12 months, or more often for bigger systems.

Should we choose wall units or ceiling cassettes?

Wall units suit private offices and meeting rooms, and cost less to fit. Cassettes suit open-plan rooms with a suspended ceiling, because they spread the air four ways from the middle of the room. We'll recommend one at the survey.

Can different rooms have different temperatures?

Yes. With a multi-split or separate systems, each room has its own controller, so a meeting room can run cooler than a quiet office next door.

Can the system heat the office in winter too?

Yes. The systems we fit are reversible heat pumps, so the same units heat the office efficiently in winter.

How often should office air conditioning be serviced?

At least once a year, and twice a year for busy or heavily used spaces. LG asks for two services a year to keep its warranty valid. Where an F-Gas leak check is needed, we do it on the same visit.