Skip to content

Can I do my own planning drawings for air conditioning?

Yes. No law says who may draw plans for a planning application, listed building consent or an estate's consent. What matters is that the drawings meet the validation rules, and that they show what an air conditioning install really involves. Here is what councils check, the plans and scales you need, what goes wrong, and what an air conditioning application has to show.

householder fee from 1 April 2026 £548

Scaled line drawings of a house elevation and floor plan on a desk with a scale ruler, pencils and a laser measure
householder fee from 1 April 2026
£548
usual location plan scale
1:1250
usual plans and elevations
1:50 or 1:100
Planning Portal limit per file
10 MB
On this page14 sections

The short answer: yes, you can draw your own

The Development Management Procedure Order 2015 asks for plans and drawings drawn to an identified scale, with north shown on plans. It sets no qualification for the person who draws them.

  • ARB, which regulates architects, says anyone, architect or not, can legally provide architectural services in the UK
  • Only the title 'architect' is protected, by section 20 of the Architects Act 1997
  • So the question isn't whether you're allowed. It's whether your drawings are valid, and then whether they show enough for an officer to say yes
  • Bath's council, learning from unsuccessful applications, says objections arise where plans and drawings are not of a professional standard, lack detail or are inaccurate
  • A tidy drawing that leaves out the pipe route or the unit's size can be valid and still be refused
  • First check whether you need drawings at all: a heating-capable system on a house is often permitted development, as our planning permission guide explains
  • Drawings are needed for a listed building, a flat, a cooling-only unit, a road-facing wall in a conservation area, an Article 4 area, or an estate with its own consent scheme

What the law and the council ask for

Article 7 of the 2015 Order says an application must be on the published form, with a plan identifying the land and any other plans, drawings and information needed to describe the development.

  • Councils can add items through a local validation list, but only if it was published in the two years before your application
  • The item must also be reasonable for the size of the job and likely to matter to the decision
  • Design and access statement: needed with every listed building consent application
  • An ordinary householder application doesn't need one: article 9 only asks for major development, or new homes or 100 m² or more of floor space in a conservation area or World Heritage Site
  • Ownership certificate: A if you own the whole property, B if others do, such as a freeholder, who must be told
  • Fees: in England from 1 April 2026, a householder application costs £548, and so does a full application for one flat
  • Listed building consent has no fee. The Planning Portal adds a service charge on some online applications
  • Some councils deduct a charge if an invalid application isn't put right in time: St Albans takes £28 from a householder fee after 21 days

The drawings an air conditioning application needs

The usual set for a split system or multi-split on a house. Your council's local list and any estate rules can add to it.

DrawingUsual scaleWhat it must show
Location plan1:1250 or 1:2500The property edged in red on an up-to-date licensed map, with enough roads named to find it
Block or site plan1:500 or 1:200The house, boundaries and neighbours, the outdoor unit's position and its distances to boundaries and neighbours' windows
Existing elevations1:50 or 1:100Every wall that will change, as it is today, including any old units, brackets or pipes
Proposed elevations1:50 or 1:100The outdoor unit to scale, its bracket or ground frame, pipe and drain routes, wall openings and any screen
Existing and proposed floor plans1:50 or 1:100Each indoor unit, the pipe, cable and condensate routes, and where they pass through walls
Roof or loft plan1:50 or 1:100Needed for a flat-roof unit, which must stay 1 m from the edge for permitted development, or a ducted system
Unit and screen detail1:20The pad or frame, anti-vibration mounts, enclosure material and colour, and the maker's airflow clearances
Product data and photosNot to scaleModel, dimensions, colour and sound data, and photos with the proposed positions marked

Location plans: the one people get wrong

Planning practice guidance says a location plan should be based on an up-to-date map, typically at 1:1250 or 1:2500, fitting A4 or A3 where possible.

  • It must show enough roads and buildings to identify the site, edged clearly with a red line around all the land needed
  • Other land you own nearby goes in blue
  • Barnet wants at least two named roads, and for a householder application the red line goes around the house and garden
  • Ordnance Survey maps are copyright: councils expect a plan from a licensed supplier, and a screen grab or tracing of an old map isn't one
  • A licensed plan comes with a licence to use it for your application. Keep the copyright and licence statement printed on it
  • The Planning Portal's location plan tool is included in its service charge when you apply online. It has no block plan tool, and points to its accredited supplier
  • Licensed plans are cheap: when we checked, ReQuestaPlan charged £11 for a 1:1250 location plan PDF and £8.50 for a 1:500 block plan
  • UK Planning Maps started from £8.50
  • Draw your red line in the supplier's tool, or on the PDF without changing the map itself

Block plans and site plans for an outdoor unit

A block plan, usually at 1:500 or 1:200, shows the property, its boundaries and the buildings next door. For air conditioning it's where you prove the position works.

  • Barnet asks for the relationship of the proposal to the site boundary and any buildings on adjacent land
  • Mark the outdoor unit and dimension it to the boundaries and to the nearest neighbouring windows
  • Those distances matter more than people expect: permitted development depends on the MCS 020(a) calculation
  • It must come out at 37 dB(A) or lower 1 metre outside each neighbouring habitable room window or door
  • Letchworth: at least 1 metre from any boundary
  • Wentworth: 3.5 metres from the boundary unless the unit is soundproofed
  • Bournville: 4 metres from neighbouring properties

What councils check before they validate

From Lambeth's ten common reasons for invalid applications, Barnet's drawing requirements and Kensington and Chelsea's validation list. Fail one and the eight-week clock doesn't start.

  • Every drawing to a recognised scale, with the scale stated at a stated paper size, such as 1:50 at A3
  • A scale bar on every drawing, and a north point on every plan
  • A title and a unique drawing number on every sheet, with revision letters when drawings change
  • Metric dimensions only: Barnet won't accept imperial units
  • No freehand sketches or pencil drawings, which Barnet says are not acceptable
  • Existing and proposed clearly labelled, and plans and elevations that match each other
  • A red line on the location plan around all the land involved
  • Neighbouring buildings and their windows shown where they are close
  • The right ownership certificate, signed and dated, and the right fee
  • A design and access statement with any listed building consent application
  • Noise information where your council's local list asks for it, as Kensington and Chelsea's does for every air conditioning unit

Scales, paper sizes and files

Kensington and Chelsea's list is a good standard to work to wherever you are.

  • Drawings clearly titled with unique references and revision labels
  • A scale bar showing lengths of 1 m and 10 m, and a north arrow
  • The paper size printed with the scale, such as 1:50 at A3 or 1:100 at A3
  • A3 is the largest sheet it takes online, with a 5 MB limit per file and 25 MB per application
  • The Planning Portal takes files of up to 10 MB each, and PDF is the safest format
  • Export at true scale and check it prints at actual size rather than fit to page
  • Leave off any 'do not scale' note: a planning drawing exists so the officer can measure from it
  • No council or national rule we found says which software you must use. A free 2D CAD program such as LibreCAD will do if the result meets these standards
  • What takes the time is the survey: accurate measurements of every wall, window and room you're drawing

What an air conditioning drawing must show that a builder's drawing doesn't

Most guides to DIY planning drawings are written for extensions. An air conditioning application is judged on different things: where the unit is seen from, how loud it is, and what the pipes and fixings do to the building. The officer needs to see all of it.

  • The outdoor unit drawn to its real size, with exact dimensions: Welwyn Garden City criticised an application in 2025 for leaving them out
  • The maker's airflow clearances around the unit, inside any screen or enclosure
  • How it's fixed: a ground pad or frame, or a wall bracket, with anti-vibration mounts
  • The full refrigerant pipe and cable route, inside and out, and where it passes through the wall
  • Where the condensate goes: an internal waste or a drain, or a gravel soakaway at the base
  • The unit's colour, and the material and finish of any screen or pipe cover
  • The street view and the view from neighbouring gardens, with photos to show it can't be seen
  • The maker's sound data and the distance to the nearest neighbouring window
  • For a heat pump that also cools, the heating role and the shading and ventilation already in place

What estates and trusts ask for

Estate consent sits on top of planning, and several estates set their own drawing rules. Read October 2026.

Estate or trustDrawingsAlso asked for
Hampstead Garden Suburb Trust1:1250 OS location plan; plans, elevations and sections at 1:50 or 1:100, minimum 1:50 at A3Position and material of all external pipework, existing and proposed; adjoining buildings shown
Letchworth Heritage FoundationPlans and elevations at 1:50 or 1:100 with a scale bar, readable at A3; site plan at 1:500 or 1:200Neighbouring properties, trees and hedges; pipe size, colour, type and materials
Welwyn Garden City Estate Management SchemeLocation and site plans; elevations and floor plans at a scale such as 1:50 or 1:100An application statement; a method statement if requested; the unit's dimensions
Dulwich EstateOne PDF, no larger than A3, not less than 1:100, with a title block; new work outlined in redNeighbours' building lines; site photos; a detailed acoustic report
GrosvenorConcept drawings first, then drawings at not less than 1:50 through its portalGrosvenor may appoint its own acoustic or mechanical engineer, at your cost
CadoganExisting and proposed drawings with a title block, dated and numbered, as PDFPosition of all external plant; an acoustic engineer's report to the council's criteria

If you draw it yourself

  1. Check you need to apply

    Use our planning checker for listing, conservation areas and Article 4 directions at your postcode, and check your deeds for an estate scheme. If the system is permitted development and there's no estate, you may need no drawings at all.

  2. Get the rules first

    Download your council's local validation list and, if there is one, the estate's guidance and form. Note the scales, paper sizes and extra documents each wants.

  3. Measure and photograph

    Measure every wall, window and room you'll draw, to the nearest 10 mm, and photograph each elevation square on, the street view and the neighbours' windows.

  4. Buy licensed OS plans

    Buy a 1:1250 location plan and a 1:500 block plan from a licensed supplier, or use the Planning Portal's location plan tool when you apply.

  5. Get the unit data from the installer

    Ask your installer for the exact model, dimensions, clearances, colour, sound data and the pipe and condensate route. You can't draw the proposal without them.

  6. Draw existing, then proposed

    Draw what's there now, copy it, then add the unit, pipes and any screen. Title, number and scale every sheet, label existing and proposed, and export to PDF at true scale.

Where the design pack fits

If you'd rather not, that's what our design pack is. Our installation design team surveys the house and produces the drawings for you.

  • Location and block plans on licensed mapping
  • Existing and proposed elevations and floor plans at 1:50 or 1:100
  • The unit, screen, pipe and condensate details, and the equipment schedule
  • The maker's sound data and our MCS 020 calculation, marked photos and the technical text for your statement
  • We're air conditioning installers, not architects: where you need a heritage statement or an acoustic report, we tell you at the start and can introduce specialists
  • It's from £795, and can be more for a larger house, more units, a higher listing grade or a council that asks for more
  • You agree a fixed fee in writing first and pay it in full when you accept
  • It's payable whether or not consent is granted, because the council or the estate decides
  • One round of changes is included
  • If you accept our installation quote within 6 months of receiving the pack, the full fee comes off the installation

Planning drawing questions

Can I submit my own drawings for planning permission?

Yes. The law sets no qualification for whoever prepares planning drawings. The council checks that they are drawn to a stated scale, show north on plans, are clearly labelled existing and proposed, and come with a red-line location plan on licensed mapping and anything on its local validation list. If they meet those rules, they're valid whoever drew them.

Can I draw my own plans for planning permission by hand?

Some councils won't accept them. Barnet says freehand sketches and pencil drawings are not acceptable and that drawings must use metric measurements. A neat ink drawing to an accurate scale, with a scale bar and title, may be accepted elsewhere, but many applications now go in online, so a scaled PDF from CAD software is the safer route.

Do I need an architect for air conditioning planning drawings?

No. Only the title 'architect' is protected by law, not the work. ARB says anyone, architect or not, can legally provide architectural services. For an air conditioning application the hard parts are technical: unit size and clearances, pipe and condensate routes, fixings and sound data. Where a listed building needs a heritage statement, that comes from a heritage specialist.

What scale should a location plan be for a planning application?

Usually 1:1250, or 1:2500 for a large or rural site, fitting on A4 or A3. It must be based on an up-to-date map, show enough roads and buildings to find the property, and have the site edged clearly in red. Buy it from a licensed Ordnance Survey supplier or use the Planning Portal's location plan tool.

What is the difference between a location plan and a site plan?

The location plan, at 1:1250 or 1:2500, shows where the property is in its neighbourhood. The site or block plan, usually at 1:500 or 1:200, zooms in on the property itself: the house, boundaries, neighbouring buildings and, for air conditioning, the outdoor unit with its distances to the boundaries and the nearest neighbouring windows.

Can I use an estate agent's floor plan or the old drawings on the council website?

Only as a reference. Both are copyright works, and estate agent plans are often marked for illustration only and are rarely to scale. Approved drawings on the council's planning register help you check the layout, but redraw from your own measurements rather than copying them without the author's permission.

Do I need a design and access statement for air conditioning?

Not for an ordinary householder application. You do for every listed building consent application, and it must explain how the design takes account of the building's special interest, its features and its setting. Where you apply for planning permission and listed building consent together, councils such as Barnet accept one statement for both.

What do listed building consent drawings need to show?

Everything an ordinary application shows, plus the effect on historic fabric: where each pipe and cable runs inside and out, how and where every fixing is made, the size and position of new holes, which existing holes and routes are reused, indoor units kept clear of decorative features, and how the system could later be removed. Historic England says routes and fixing methods should be recorded on the drawings.

Can I use your drawings with a different installer?

Yes, once the fee is paid, for your own home. We keep the copyright, so they can't be reused for another property. The installer who fits the system is responsible for following the consent and its conditions.