Why new-build homes get so hot, and what actually fixes it

New homes are built to hold heat in. That's good news in January and the reason your bedroom is still 27°C at midnight in July. Add big windows, one outside wall and a top-floor position and a new flat can be the hottest home on the street. Here's the physics, the rules that now apply to new homes, who's responsible, and what you can do about it.

Man on a grey sofa in a bright top-floor new-build flat, floor-to-ceiling glazing with blinds half down, a white wall-mounted air conditioning unit running
overheating rules for new homes began
15 June 2022
new homes the CCC said would overheat
570,000
outdoor unit limit on a block of flats
0.6 m³
UKHSA: fans help below this
35°C
On this page15 sections

New homes keep heat in

A new home has thick insulation, sealed joints and good double or triple glazing. In winter that keeps the heating bill down; in summer, once heat gets in, it has nowhere to go.

  • Heat gets in through glass, through the roof, or from cooking and appliances
  • UKHSA's keep cool at home checklist says plainly that some highly insulated or energy-efficient homes may trap heat inside
  • In 2019 the Climate Change Committee estimated that around 20% of homes in England, about 4.5 million, overheat even in cool summers
  • In June 2021 it told the government that 570,000 new homes built since its previous assessment five years earlier would be likely to overheat in hot summers
  • It warned that heat-related deaths in the UK could rise from an average of 2,000 a year to 7,000 by 2050
  • The Hot Homes project, run by the University of Glasgow's Urban Big Data Centre with the Bureau of Investigative Journalism, tracked 40 homes in Southwark for six weeks in summer 2023
  • Every home went above 25°C, and many recent builds were among the hottest
  • UCL's Anna Mavrogianni said the findings showed overheating is a current problem, in particular in more energy-efficient, newly built homes

Big windows and one outside wall

Modern flats sell on light, so they get floor-to-ceiling glass. Sun through glass is the biggest source of summer heat in any home.

  • Government-commissioned modelling by AECOM, published in 2019, tested eight types of new home in five English locations
  • All of them failed the industry's overheating test in a moderately warm summer, and London was the worst location by a wide margin
  • Flats failed in bedrooms as well as living rooms, mainly because they have more glazing relative to floor area, so they pick up more solar gain
  • Single-aspect layouts: with windows on one side only, air can't flow through, so opening every window on a still evening does little
  • The Zero Carbon Hub, reporting in 2015, found overheating most common in smaller single-aspect homes where cross-ventilation is hard to achieve
  • The building rules now define cross-ventilation as openings on opposite façades. A corner flat with windows on two adjoining sides doesn't count
  • Orientation: a south-facing flat takes the sun all day; a west-facing one catches the low, strong evening sun just when you want it to cool down
  • UKHSA lists large east, west or south-facing windows without shade, and homes with opening windows on one side only, as more likely to overheat

Top floors, dark roofs and heat from inside

Heat rises, so the top floor of a house and the top flat in a block collect warmth from every floor below, right under a roof that's been in the sun since morning.

  • UKHSA names flats on the top floor as more likely to overheat because heat rises
  • A flat roof with a dark finish, or dark tiles over a thin loft, makes it worse
  • Heat you make: ovens, hobs, fridges, tumble dryers, TVs, games consoles, laptops and people all give off heat, and in an airtight home it stays
  • In many new blocks, hot water and heating pipes run through corridors and risers all year
  • In the Hot Homes study, homes on communal heating averaged more than 1°C hotter than those without it
  • MVHR: many new homes have this whole-house ventilation, which recovers heat from the stale air it extracts and passes it to the fresh air coming in
  • In winter that's the point. In summer, if the summer bypass isn't working or isn't enabled, it keeps warming the incoming air
  • Check the controller, and ask whoever maintains it whether the bypass is active and the filters are clean

Why is my house so hot when it's cold outside?

This is the new-build question we hear most, and it has the same answer as the summer one. Insulation doesn't care which season it is: it holds whatever heat is in the house.

  • A home that loses very little heat warms up from the inside: a few people, a hob, a dryer and a TV can lift the temperature several degrees
  • Low winter sun through a big south-facing window adds more
  • Underfloor heating in a screed floor takes hours to respond, so a sunny afternoon can leave a room overheated long after the thermostat is satisfied
  • If the house is warm on a cold day, turn the heating down and check the MVHR isn't set to a boost mode
  • Open a window for ten minutes rather than living with it

Approved Document O: the overheating rules since June 2022

Since 15 June 2022, new residential buildings in England have had to meet requirement O1 of the Building Regulations, explained in Approved Document O.

  • Reasonable provision must be made to limit unwanted solar gains in summer and provide an adequate means to remove heat from the indoor environment
  • Account must be taken of occupants' safety and reasonable enjoyment of the home, and mechanical cooling may only be used where insufficient heat can be removed without it
  • Simplified method: a maximum glazing area and minimum opening area by orientation, cross-ventilation and location
  • England is moderate risk, except the urban parts of London listed by postcode in the document, which are high risk
  • In high-risk London, a flat with no cross-ventilation whose biggest windows face west is limited to glazing of 11% of its floor area; with windows on opposite sides, 18%
  • High-risk homes also need shading: external shutters, low solar-gain glass or overhangs
  • Dynamic thermal modelling: the alternative, to CIBSE's TM59 method, with limits set by the document
  • Windows are assumed likely to stay closed at night where bedroom noise would exceed 40 dB averaged over the night, or 55 dB more than ten times a night
  • Only openings that can be left open securely count towards ventilation, especially in ground-floor and easily reached bedrooms
  • Transitional rule: it doesn't apply where a building notice, full plans or initial notice went in before 15 June 2022, if work started before 15 June 2023
  • So a flat completed in 2023 or 2024 may have had no overheating check at all, and anything finished before 2022 almost certainly didn't
  • That's why two new-looking blocks on the same road can behave so differently in a heatwave

Does Part O apply to your home?

The date that matters is when the plans went in to building control, not when you moved in. The developer, or your council's building control team, can tell you.

Your homePart OWhat it means
Completed before June 2022NoNo overheating requirement at design stage. Glazing and ventilation were set by energy and ventilation rules only.
Plans in before 15 June 2022, started before 15 June 2023NoExempt under the transitional rule, even if it finished in 2024 or later. Ask the developer which rules it was built to.
Plans in on or after 15 June 2022YesDesigned to limit solar gain and remove heat, with usable openings. Shading required in the high-risk part of London.
Older home, extended or convertedUsually noThe document covers new residential buildings. Check with building control if your home was converted from another use.

Who is responsible: the developer, the warranty or you?

A hot home is rarely a defect in the legal sense, so overheating on its own isn't usually claimable. A failure to build what was approved can be.

  • NHBC Buildmark, years one and two: the builder must put right defects you report, where a defect means a breach of NHBC's requirements
  • Years three to ten: NHBC insures against damage caused by defects in specified structural parts, such as foundations
  • It excludes gradual deterioration, wear and tear, and any alteration or addition you make after NHBC's final inspection
  • What can be claimed: a missing MVHR summer bypass, or windows that don't open as far as the design assumed
  • Also restrictors fitted where the overheating strategy relied on wide openings, or shading shown on the drawings and never fitted
  • Those are snagging and building-control matters, and in a post-2022 home they go to the heart of Part O compliance
  • Put them in writing to the developer within the two-year period, with photos and temperature readings
  • In a flat: the outside of the building belongs to the freeholder or management company, which matters for anything fixed to a wall or balcony
  • Your lease will say what needs consent, and it nearly always covers external changes. Our guide to air conditioning in a rented or leasehold home goes through how to ask

What you can do yourself, in order

  1. Shade the glass before the sun arrives

    UKHSA advises shading or covering windows in direct sun. Close blinds or curtains before the sun reaches a window, not after the room is hot. Light-coloured, lined blinds work better than dark ones. External shutters, roller blinds and awnings are more effective still, but on a flat they need the freeholder's consent.

  2. Purge the heat at night

    Open windows when the air outside feels cooler than inside, usually late evening to early morning, if it's safe and quiet enough. Open rooms on both sides of the home and the internal doors between them, so air can pass through. Shut everything again before the sun gets up.

  3. Try reflective film on the worst window

    Solar control film on the inside of a south- or west-facing pane cuts the heat coming through it. It also cuts light and changes how the window looks from outside, so check your lease or estate rules first, and ask the glazing supplier whether film is allowed on your sealed units without affecting the glass guarantee.

  4. Use fans the right way

    UKHSA says electric fans help when the air temperature is below 35°C, and not to aim a fan straight at your body. A fan in a window blowing hot air out at night, with another window open elsewhere, shifts more heat than a fan pointed at the sofa.

  5. Make less heat indoors

    Cook earlier or later, use the microwave or air fryer rather than the oven, dry washing outside or on the balcony, turn off standby appliances and lights, and run the dishwasher and tumble dryer late at night. In a new build every one of these shows on the thermometer.

  6. Check the MVHR and the heating

    Make sure the MVHR summer bypass is enabled and the filters are clean, and that the heating, including underfloor heating and towel rails, is actually off. If the hot water cylinder or pipework in a cupboard is warm to the touch, ask the developer or management company about insulating it.

  7. Then consider air conditioning

    If a bedroom still won't drop below the mid-twenties at night after all that, the passive options have run out. A split system takes heat out of the room rather than moving it around, and heats the same room in winter.

When air conditioning is the right fix in a new build

The London Plan and Approved Document O both put air conditioning last, after shading, ventilation and reducing heat gains, and we agree with the order.

  • But for a top-floor, single-aspect flat facing west, or a loft bedroom with a roof window, passive measures often can't get the night-time temperature down on their own
  • That's the home a wall unit is designed for
  • Easy installs: cavity or timber-frame walls take a core drill cleanly, and pipe runs are short
  • On a house the outdoor unit goes on a side or rear wall, or on a ground pad, away from the neighbour's bedroom window
  • On a flat it goes on the balcony, in a recess, or at ground level for a ground-floor flat, with the condensate taken to a drain
  • A balcony unit needs the freeholder's written consent and a check that the balcony structure and any drainage can take it; our flats page covers the options
  • Winter: most new estates have no gas, and electric panel heaters are expensive to run
  • A split air conditioner is an air-to-air heat pump, delivering several units of heat for each unit of electricity, so it can heat the room in January for less than a panel heater
  • Permitted development actually requires the unit to be capable of heating, as the next section explains

Planning rules for new-build houses and flats

In England, an air source heat pump on a home, which is what a heating-capable split system is, can be permitted development under Class G of Part 14 of the General Permitted Development Order. The rules were rewritten from 29 May 2025.

  • The unit must comply with the MCS Planning Standards, which set the noise limit at neighbours' windows
  • No more than one heat pump on a terraced or semi-detached house or a block of flats, or two on a detached house
  • The outdoor unit can't be bigger than 1.5 m³ on a house or 0.6 m³ on a block of flats
  • It can't go on a pitched roof, or within 1 m of the edge of a flat roof
  • Outside a conservation area, not on a wall facing a road above ground-floor level; inside one, not on any wall or roof facing a road, or nearer the road than the building
  • Listed buildings and scheduled monuments are excluded
  • It must not be used solely for cooling, which rules out cooling-only units, and it must be removed when no longer needed
  • The catch for new flats: once a neighbour has a unit, yours needs a planning application
  • The permission for your phase may carry a condition removing permitted development rights for changes to the outside of the house
  • The transfer deed may have a covenant requiring the developer's or estate company's consent for anything fixed to an outside wall
  • Neither replaces planning law; they sit on top of it. A Lawful Development Certificate gives you a written answer from the council

Before you spend money on a unit

Ten minutes of checking saves a wasted quote. We go through all of this at the survey, but you can start now.

  • Measure it: put a cheap thermometer in the hottest bedroom and note the temperature at bedtime and at 6am for a week
  • Work out which way the big windows face, and whether the home has windows on opposite sides
  • Try the free fixes for a fortnight: shade by day, purge at night, less heat indoors, MVHR bypass on
  • Ask the developer which building regulations the home was built to, and whether an overheating assessment was done
  • If the home is under two years old, report anything that doesn't match the design, such as windows that won't open fully, in writing
  • Read your lease or transfer deed for anything about external equipment, balconies and alterations
  • Find the planning permission for your phase on the council website and read the conditions for removed permitted development rights
  • In a flat, ask the management company whether any unit has already been fitted to the block, and what its consent process is
  • Check how the home is heated, and what it costs; a heat-pump split system may replace electric heating in that room
  • Decide where an outdoor unit could sit: balcony, side wall, rear wall or ground pad, away from your own and neighbours' bedroom windows
  • Get the unit's size, sound level and position in writing to send to the freeholder or management company with your request

New estates near us

We're based in Luton and most of the new-build homes we survey are on the estates around us. Each of these has its own area page with the local planning and estate rules:

  • Wixams, south of Bedford: up to 4,500 homes in the original masterplan, almost all of them new, split between Bedford Borough and Central Bedfordshire. See our Wixams page.
  • Linmere and Bidwell West, Houghton Regis: up to 5,150 and 1,850 homes, about 750 occupied at Linmere so far, plus estate covenants and management company rules on top of planning law. See our Houghton Regis page.
  • Napier Park, Luton: the former Vauxhall plant off Kimpton Road, with outline permission since 2014 for 625 homes, and new flats where freeholder consent comes first. See our Luton page.
  • Hemel Hempstead: Hemel Garden Communities plans around 11,000 homes to the north and east of the town by 2050, some of it in St Albans district. See our Hemel Hempstead page.
  • Barking Riverside and Barking town centre: where most of the borough's new blocks have gone up, with 28 per cent of households now in purpose-built flats. See our Barking and Dagenham page.

What it costs to cool a new-build bedroom

New homes are well insulated, so a bedroom usually takes the smallest unit. Every price is fixed in writing after a free survey.

  • A bedroom or study

    2.5 kW wall unit, 5 m pipe, fitted in a day

    from£1,850
  • A living room

    3.5 kW wall unit

    from£2,050
  • Open plan or a loft

    5 kW wall unit

    from£2,450

New-build overheating questions

Why is my new build so hot in summer?

Because it's built to keep heat in. High insulation and airtightness stop heat escaping, large windows let the sun pour in, and in a flat with windows on one side there's no breeze to carry heat out. Government modelling found new flats fail overheating tests mainly because they have more glass relative to floor area. Shade the glass by day, ventilate at night, and cut the heat you make indoors.

Why is my new-build flat hotter than my old house was?

An older house leaked heat through its walls, roof and gaps, and usually had windows on more than one side. A new flat holds heat, often has one outside wall, and may sit under a flat roof or above a corridor full of warm pipes. The Hot Homes study in Southwark found homes on communal heating averaged more than 1°C hotter than those without it.

Are new homes supposed to overheat? Isn't there a rule against it?

There is now. Approved Document O has applied to new residential buildings in England since 15 June 2022. It requires designs that limit solar gain and remove heat, using passive means before mechanical cooling. Homes whose plans went in before that date, and started before 15 June 2023, were exempt, which is why many homes finished in 2023 and 2024 were never checked.

Can I complain to the developer or claim on the NHBC warranty?

Overheating on its own isn't normally a defect. What you can report, in the first two years, is anything that doesn't match the approved design: a missing MVHR summer bypass, windows that don't open as the design assumed, or shading that was never fitted. NHBC's Buildmark covers defects reported in years one and two and damage from specified structural defects in years three to ten. It excludes alterations you make yourself.

Why is my house so hot upstairs?

Warm air rises through the house and collects on the top floor, which is also the floor under the roof. In a new home the insulation then holds that heat into the night. Shade upstairs windows by day, open them when the air outside is cooler, and if a bedroom still won't cool, that's the room for a wall unit.

Why is my house so hot when it's cold outside?

A home that barely loses heat warms up from the people, cooking and appliances inside it, plus low winter sun through big south-facing glass. Underfloor heating in a screed floor also keeps giving off heat for hours after the thermostat clicks off. Turn the heating down, check the MVHR setting, and air the room briefly rather than putting up with it.

Can I put air conditioning in a new-build flat?

Usually, with the freeholder's or management company's written consent for the outdoor unit on the balcony or wall. Planning-wise, one heat pump per block of flats with an outdoor unit up to 0.6 m³ can be permitted development; a second needs an application. Check your lease, the estate rules and any planning condition on the block first. We supply the unit size, sound data and drawings for your request.

Will air conditioning cost a fortune to run in a new build?

Less than in an older home. A well-insulated room holds its cooled air, so the unit runs for less of the day once the room is down to temperature. A small bedroom unit uses a fraction of the electricity of the cooling it delivers, and less again once it's only holding the room steady. In winter the same unit heats the room as an air-to-air heat pump, which usually costs less than an electric panel heater.