R32 vs R290: which refrigerant should your air conditioning use?

For most UK homes today, R32. It's what almost every split wall unit uses, it's legal in GB with no ban date set, and every installer can service it. R290 (propane) has a far lower climate impact, and the first UK wall units are here, but the choice is small and it's highly flammable, so charge sizes are tightly limited.

Air conditioning engineer kneeling beside an outdoor unit on a London garden wall, a digital gauge set connected with red, blue and yellow hoses
GWP, R32 vs R290 (GB law)
675 vs 3
flammability class
A2L vs A3
GB ban that ended R410A splits
1 Jan 2025
for any GB ban on R32 splits
No date
On this page6 sections

R32 vs R290: the verdict

R32

The standardMost units we fit, from £1,850 fitted

R290 (propane)

Lowest impactQuoted individually
VS
Our verdictR32 for most homes

R32 is the sensible choice for most homes now: a wide choice of efficient units, every engineer can service it, and no GB ban is set. R290 wins on climate impact by a mile and is worth a look for one or two rooms, if a unit suits.

Climate impact
R32: 5R290 (propane): 10
Flammability
R32: 7R290 (propane): 4
Choice of units
R32: 10R290 (propane): 3
GB rules
R32: 8R290 (propane): 10
Servicing support
R32: 10R290 (propane): 5

Round by roundR32 3R290 (propane) 2Level 1

  • Climate impactGWP 3 against 675R290 (propane)
  • FlammabilityA2L mildly flammable against A3 highly flammableR32
  • ChoiceAlmost every UK split against a handfulR32
  • GB rulesBoth legal for new splits; no GB ban dateLevel
  • EU rulesEU bans R32 in new air-to-air splits from 2029R290 (propane)
  • ServicingEvery F-Gas engineer; R290 needs A3 tools and trainingR32

R32

The standard

Best for

  • Any room, from a box room to open plan
  • Several rooms on one outdoor unit
  • The widest choice of brands and designs

Skip it if

  • The lowest possible climate impact is your priority
  • You live in the EU and plan ahead for 2029

Pros

  • GWP 675, a third of R410A
  • Mildly flammable A2L
  • Used across Daikin, Mitsubishi, Samsung, LG

Cons

  • Still an F-gas with F-Gas rules
  • Banned in new EU splits from 2029

R290 (propane)

Lowest impact

Best for

  • The lowest climate impact available
  • A single bedroom or study
  • Homes that want to be ahead of future rules

Skip it if

  • You need a multi-split or a big room
  • You want the widest choice of models

Pros

  • GWP 3 under GB law
  • A natural refrigerant, not an F-gas
  • Outside the HFC phase-down

Cons

  • Highly flammable A3
  • Charge limited by room size
  • Few UK wall units so far

Our scores from GB law (GWP and bans), the ISO 817 safety classes, and the UK units on sale in November 2026. Climate impact is GWP; choice is how many UK wall units use it. Not a lab test.

R32, R290 and R410A side by side

FactR32R290 (propane)R410A
GWP under GB law67532,088
Safety classA2L, mildly flammableA3, highly flammableA1, not flammable
An F-gas?YesNoYes
New single splits in GBAllowedAllowedBanned under 3 kg since 2025
New air-to-air splits in the EUBanned up to 12 kW from 2029AllowedBanned
Existing systemsServiced as normalServiced as normalCan still be serviced and regassed in GB

GWP from Annexes I and IV of the retained F-Gas Regulation (AR4 basis). Mitsubishi Electric quotes R290's GWP as 0.02 on a newer basis; GB law uses 3. Safety classes from ISO 817 and BS EN 378.

Why R290 units are small

Because propane is highly flammable, the safety standard for heat pumps and air conditioners, IEC 60335-2-40, limits how much can be in a unit for a given room size. Edition 7 (2022) allows larger charges where the unit has extra safety measures such as airflow, leak detection and shut-off.

As an example, one industry summary of the change gives about 334 g for a 20 square metre room with a 2.2 m ceiling under the old rules, rising to 988 g with the enhanced design. That's why the first R290 wall units are single-room sizes: Mitsubishi Electric's MSZ-RZ comes in 2.5 and 3.5 kW.

Should you wait for R290?

In GB, there's no need. R32 single splits remain legal for new installs, no GB ban date is set, and the government said in May 2026 it would not legislate in 2026 to change the next HFC phase-down steps. An R32 system fitted now can be serviced for its whole life.

  • Choose R32 for multi-splits, larger rooms, design units and the widest choice
  • Look at R290 for one bedroom or study if a model fits the room and your budget
  • Replacing R410A? It can still be serviced and regassed, so replace when it fails or gets costly, not because of the rules

What it costs to fit

R32 wall units start from £1,850 fitted. We quote R290 units such as the Mitsubishi Electric MSZ-RZ individually, after a free survey.

  • A bedroom or study

    2.5 kW wall unit, 5 m pipe, fitted in a day

    from£1,850
  • A living room

    3.5 kW wall unit

    from£2,050
  • Two rooms, one outdoor unit

    Multi-split

    from£3,650
  • Premium range upgrade

    Quieter, more efficient unit

    from£250

R32 and R290 questions

Is R290 better than R32?

For the climate, yes: a GWP of 3 against 675. For choice and simplicity, R32 still wins: almost every split uses it, it's only mildly flammable, and every F-Gas engineer can service it.

Is R32 being banned in the UK?

Not for new single split air conditioners. GB's 2025 ban covers refrigerants with a GWP of 750 or more, which R32 is below, and no further GB date is set. The EU bans R32 in new air-to-air splits up to 12 kW from 2029.

Is R290 safe in a house?

Yes, within the safety standard's charge limits for the room, and fitted by trained engineers with the right tools. It's highly flammable, which is why units are small and rooms have a minimum size.

Which air conditioners use R290 in the UK?

Mitsubishi Electric's MSZ-RZ wall unit, in 2.5 and 3.5 kW, is one. Most UK split wall units still use R32.

What happens to my R410A air conditioner?

Nothing for now. Existing R410A systems in GB can still be serviced and regassed. New R410A single splits under 3 kg can't be sold since 2025. See repair or replace.

Does the refrigerant change the running cost?

The unit's SEER and SCOP decide that, not the gas on its own. Compare models on those figures in our spec explorer.

Sources

10
  1. legislation.gov.uk: Regulation (EU) 517/2014, Annex I (GWP of HFCs)
  2. legislation.gov.uk: Regulation (EU) 517/2014, Annex IV (GWP of other gases)
  3. legislation.gov.uk: Regulation (EU) 517/2014, Annex III (bans)
  4. gov.uk: bans on F gas in new products and equipment
  5. gov.uk: banned F gas for refilling equipment
  6. Defra: F gas regulation in Great Britain consultation
  7. European Commission: air conditioning and the F-gas rules
  8. FETA: an introduction to A2L refrigerants
  9. Cooling Post: IEC 60335-2-40 revision and propane charge limits
  10. Mitsubishi Electric UK: MSZ-RZ R290