Mitsubishi Electric error codes: what the flashing light means

Mitsubishi Electric home units don't show a code on a screen. Instead, the operation indicator lamp blinks a set number of times. Here is how to count the blinks, what each pattern means according to Mitsubishi Electric's own service manuals, what you can safely check, and when to book an engineer.

Slim white wall-mounted air conditioning unit above a sideboard in a Victorian dining room
pause between groups of blinks
2.5 seconds
Mitsubishi's advice for a sure count
Count twice
repair price before any work
Written
we repair systems others installed
Any fitter
On this page11 sections

How a Mitsubishi Electric shows a fault

When a Mitsubishi Electric home unit finds a fault, the indoor fan stops and the operation indicator lamp blinks. The number of blinks in each group points to the area of the fault.

  • MSZ-LN: the POWER lamp blinks
  • MSZ-AP: the upper lamp
  • MSZ-HR: the left lamp (upper on the larger HR60 and HR71)
  • MFZ-KT floor unit: the left lamp
  • The unit remembers the last fault after the lamp stops blinking, and an engineer can recall it with a set-up sequence on the remote
  • So it's worth mentioning a fault that cleared by itself

How to read the blinking lamp

  1. Spot the fault

    The indoor fan stops and the lamp on the front of the indoor unit starts blinking.

  2. Count the blinks

    Blinks come half a second apart. Then the lamp goes off for about 2.5 seconds before the group repeats. A phone video makes counting easier.

  3. Count two groups

    Mitsubishi Electric's manuals say to check at least two full cycles before deciding the number.

  4. Check for even blinking

    If the lamp blinks on and off evenly with no long pause, that's the communication fault in the first row of the table below.

  5. Note the model number

    Photograph the label on the side of the indoor unit, and the outdoor unit's label too if you can see it safely.

Multi-split outdoor faults the engineer reads

On an MXZ multi-split, the engineer puts the remote into fault recall mode and counts the indoor lamp again. These patterns are different from the table above, so don't mix them up. They're here so you know what the engineer is talking about.

Recall blinksWhat it meansWhen to book
2 blinksCompressor overcurrent cut-out 3 times in a row within a minute of startingBook a repair
3 blinksAn outdoor temperature sensor open or short circuitBook a repair
4 blinksOvercurrent through the power module driving the compressorBook a repair
5 blinksDischarge temperature too high, above 116°C on 2-room modelsBook an F-Gas engineer: refrigerant amount is among the checks
6 blinksHigh pressure: outdoor coil above 70°C in cooling, or indoor gas pipe above 70°C in heatingBook an F-Gas engineer
7 blinksInverter fin above 90°C or outdoor board above 80°C. The first check is around the outdoor unitClear the outdoor unit's surroundings, then book if it returns
8 blinksOutdoor fan motor failed 3 times within 30 seconds of startingBook a repair
9 blinksOutdoor board memory can't be read, or the power module or compressor winding has shortedBook a repair
10 blinksDischarge temperature stays too low for over 40 minutesBook an F-Gas engineer
11 blinksCompressor current sensor or supply voltage faultBook a repair
14 blinksStop valve fault, a refrigerant leak sensed indoors, or an indoor unit that isn't compatibleBook an F-Gas engineer
17 blinksClosed valve or air in the refrigerant circuit detectedBook an F-Gas engineer

Source: Mitsubishi Electric service manual OBH790P (MXZ-2F, 3F, 4F, 5F and 6F), outdoor unit failure mode recall for 2-room MXZ-2F models, checked October 2026. Larger MXZ models use a similar table with small differences.

Multi-split: one room won't start

On a multi-split, a room that won't start isn't always a fault. Mitsubishi Electric's manuals say that if one room is set to cooling or dry and another to heating, the room switched on first takes priority and the other unit's lamp blinks. Set every room to the same mode and the waiting unit should start.

Mitsubishi Electric's manual also notes that if a unit starts while the outdoor unit is defrosting, warm air can take up to 10 minutes. That's normal in cold weather.

Safe checks before you book

Anyone can do these safely. If the same pattern comes back, stop resetting and book a visit.

  • Write down the number of blinks and the model number from the indoor unit's label
  • Check the remote's batteries, and that every room on a multi-split is set to the same mode
  • Switch off, then clean the air filters behind the front panel, as your user manual shows
  • Clear leaves, bins or covers from around the outdoor unit, keeping hands away from the fan
  • Do one power reset: switch off with the remote, then at the isolator or breaker, wait a few minutes, switch on
  • If a breaker trips again, leave it off and book an engineer

Booking a Mitsubishi Electric repair

We repair Mitsubishi Electric wall, floor and multi-split systems whoever installed them. Tell us the blink pattern, the model number and when it started when you book, and we'll tell you what it usually means before the visit.

We confirm the cost of the visit when you book. On the visit, the engineer reads the stored fault, confirms the cause and gives you a written price for the repair before any work starts. Refrigerant work is done by our F-Gas and REFCOM certified engineers. Visits are booked ahead, not same day.

Mitsubishi Electric error code questions

Why is the light flashing on my Mitsubishi Electric air conditioner?

It means the unit has found a fault and stopped the indoor fan. The number of blinks in each group tells you which area the fault is in. Count two full groups, then check the table above. On a multi-split, a blinking lamp can also mean another room is set to a different mode.

What does 5 flashes mean on a Mitsubishi Electric?

On MSZ-LN, MSZ-AP, MSZ-HR and MFZ-KT units, 5 blinks means the compressor has stopped for overcurrent, or failed to start, 3 times within a minute of starting. Mitsubishi Electric's checks include the stop valves, the compressor and the inverter, so it needs an engineer.

What does 2 flashes mean on a Mitsubishi Electric?

Two blinks means the indoor coil sensor or the room temperature sensor is reading as open or short circuit. It's a sensor or wiring fault inside the indoor unit, so switch off and book an engineer to test the sensors.

Why is the light blinking evenly with no pause?

Even blinking with no long pause means the indoor unit hasn't had a signal from the outdoor unit for 6 minutes. Check the breaker and do one power reset at the isolator. If it comes back, the wiring between the units or a circuit board needs checking.

How do I reset a Mitsubishi Electric air conditioner?

Switch off with the remote, then at the isolator or breaker, wait a few minutes and switch back on. That's the only reset to try yourself, and only once. If the same blink pattern returns, the fault is real and needs an engineer.

Can an engineer see past faults on a Mitsubishi Electric unit?

Yes. Mitsubishi Electric units remember the last fault even after the lamp stops blinking. An engineer recalls it with a set-up sequence on the remote, and on multi-splits can read the outdoor unit's detailed fault the same way.