Daikin error codes: what they mean and what to do
If the operation lamp on your Daikin indoor unit is blinking and the unit has stopped, it has stored a fault code. Here is how to read the code with your remote, what 33 Daikin codes mean according to Daikin's own service manual, what you can safely check yourself, and when to book an engineer.

- hold Cancel to start the check
- 5 seconds
- means the code shown is the fault
- Long beep
- repair price before any work
- Written
- we repair Daikin whoever fitted it
- Any fitter
On this page11 sections
How a Daikin tells you something is wrong
When a Daikin home unit finds a fault, the operation lamp on the indoor unit blinks. The lamp doesn't tell you which fault it is: for that, you ask the indoor unit for its code with the remote.
- Many faults stop the unit, but some are protection codes that clear by themselves once conditions return to normal, for example when an overheated part cools down
- Daikin codes are two characters, a letter and a number or two letters, such as U4 or UA
- Engineers sometimes write them with a sub-code, such as U4-00
- A code points to an area to check, not always to the failed part
- Daikin's manual gives several possible causes for most codes, in the order an engineer should test them
How to show the error code on your Daikin remote
Hold Cancel
Point the remote at the indoor unit and hold the timer Cancel button for about 5 seconds. A code starts blinking in the temperature part of the remote's display.
Step through the codes
Press Cancel again, one press at a time. Each press shows the next code and sends it to the indoor unit, which answers with a beep.
Listen for the long beep
A short beep or two beeps mean that code isn't the fault. A long, continuous beep means the code on screen is the stored fault. Write it down.
Go back to normal
Hold Cancel for 5 seconds to leave. If you don't press anything for a minute, the remote goes back to normal by itself.
Note the model number
Photograph the label on the side of the indoor unit. The model name tells an engineer which version of each code applies.
Daikin indoor unit codes
Faults Daikin's manual traces to the indoor unit, its fan, sensors or circuit board.
| Code | What it means | What you can safely do | When to book |
|---|---|---|---|
| A1 | The indoor circuit board can't set its internal settings | Note the code. One power reset at the isolator | If it returns. Checks run from the unit pairing and wiring to the board |
| A5 | Indoor coil below 0°C in cooling (freeze protection) or above 65°C in heating | Clean the filters and clear anything blocking the indoor unit. It resets itself | If it keeps happening with clean filters |
| A6 | Indoor fan motor speed not detected while the fan is driven at full power | Switch off. Don't try to turn the fan by hand | Now: the fan motor or indoor board needs testing |
| AH | Streamer unit fault (models with a streamer). The unit keeps running | Nothing to fix yourself. Cooling and heating carry on | At your next service or when convenient |
| C4 | Indoor coil (liquid) temperature sensor open or short circuit | Note the code and switch off | Now: the sensor or indoor board needs testing |
| C9 | Room temperature sensor reading out of range | Note the code. It clears if the reading returns to normal | If it returns |
| CC | Humidity sensor disconnected, broken or not communicating (models with one) | Note the code | Book a visit to test the sensor |
Daikin outdoor unit codes
Most of these are protection stops in the outdoor unit. Several have causes in the refrigerant circuit, so they need an F-Gas certified engineer.
| Code | What it means | What you can safely do | When to book |
|---|---|---|---|
| E1 | Outdoor circuit board fault: its memory (EEPROM) reads as abnormal | One power reset at the isolator | If it returns |
| E3 | High pressure switch has opened, or high pressure control ran 16 times in 300 minutes | Clear space around the outdoor unit | Now: causes include a closed valve, overcharge or blockage |
| E5 | Compressor overload (overheating). Resets after 60 seconds without a warning | Check nothing is blocking the outdoor unit | If it keeps coming back |
| E6 | Compressor failed to start: the motor doesn't turn when powered | Note the code and switch off | Now |
| E7 | Outdoor fan didn't start within 15 to 30 seconds of being told to | From a distance, look for leaves or a cover stopping the fan | If the fan is clear |
| E8 | Compressor current above the limit for 2.5 seconds | Note the code. Daikin lists outdoor temperature out of range as one cause | If it returns |
| EA | Cool and heat switchover problem | Note the code | If it stops the unit: the 4-way valve is among the checks |
| F3 | Discharge pipe temperature too high | Clear space around the outdoor unit | If it repeats: causes include the refrigerant charge or a valve |
| F6 | High pressure in cooling: the outdoor coil sensor reads too hot | Clear space and check the coil isn't covered by leaves or a cover | If it returns. Daikin's first check is a dirty outdoor coil |
| F8 | Compressor internal temperature too high, so the system shuts down | Note the code and switch off | Now |
| H0 | Compressor voltage or current sensor reading out of range before start-up | One power reset at the isolator | If it returns |
| H3 | High pressure switch reads as open while the compressor is off | Note the code | Now: the switch or board needs testing |
| H6 | Compressor didn't start within 15 seconds (position sensor) | Note the code | If it returns within minutes and the unit stops |
| H8 | Compressor input current sensor fault | Note the code | If the unit stops, or the code keeps returning |
| H9, J3, J6, P4 | An outdoor sensor out of range: outdoor air (H9), discharge pipe (J3), coil (J6), inverter fin (P4) | Note which code it is | Now: the sensor or outdoor board needs testing |
| L3 | Outdoor electrical box temperature too high | Clear space so air can flow freely around the outdoor unit | If it returns |
| L4 | Inverter cooling fin temperature too high | Clear space around the outdoor unit | If it returns. The outdoor fan and power supply are among the checks |
| L5 | Sudden overcurrent detected in the inverter | Note the code and switch off | Now |
Daikin power, refrigerant and communication codes
| Code | What it means | What you can safely do | When to book |
|---|---|---|---|
| U0 | Shortage of refrigerant detected | Switch off. Never top up or touch the pipes | Now, with an F-Gas engineer. Daikin also lists a faulty sensor as a cause |
| U2 | Power supply problem or a brief power cut detected | One power reset at the isolator | If it keeps happening: the supply needs checking |
| U4 | The indoor and outdoor units can't communicate | One power reset at the isolator | If it returns: the wiring, supply or boards need checking |
| UA | Indoor and outdoor units don't match, or the signal between them is faulty | Note the code | Now. Most often seen after an install or a part change |
| UH | Multi-split only: another indoor unit has a U0, UA or A5 fault. Resets itself | Check the code on each of the other indoor units | Book for the fault the other unit shows |
Source: Daikin Europe service manual ESIE20-11A (Split New Perfera R32), error based troubleshooting, checked October 2026. Other Daikin ranges may add codes or differ slightly.
Safe checks before you book
Safe for anyone to do. If the same code comes back, stop resetting and book a visit.
- Write down the code and the model number from the label on the side of the indoor unit
- Check the remote's batteries, and that it's set to the mode and temperature you want
- Switch off, then clean the air filters behind the front panel, as your user manual shows
- Clear leaves, bins, washing or covers from around the outdoor unit, keeping hands away from the fan
- Do one power reset: switch off with the remote, then at the isolator or breaker, wait a few minutes, switch back on
- If a breaker trips again, leave it off and book an engineer
Daikin multi-splits: check every room
On a multi-split, one outdoor unit serves two or more indoor units. If one room shows UH, Daikin's manual says the real fault is on another indoor unit: look for U0, UA or A5 on the others. UH clears by itself once that fault is fixed.
When you book, tell us the code on each indoor unit and the model number of the outdoor unit. It saves time on the visit.
Booking a Daikin repair
We repair Daikin wall, floor and multi-split systems whoever installed them. Send us the code, the model number and when it started when you book, and we'll tell you what the code usually means before the visit.
We confirm the cost of the visit when you book. On the visit, the engineer confirms the fault behind the code and gives you a written price for the repair before any work starts. Refrigerant work is done by our F-Gas and REFCOM certified engineers. Visits are booked ahead, not same day.
Daikin error code questions
What does U4 mean on a Daikin air conditioner?
U4 means the indoor and outdoor units have stopped communicating. Daikin's checks start with the power supply, then the wiring between the units, then the circuit boards. Try one power reset at the isolator. If U4 comes back, book an engineer.
What does U0 mean on a Daikin?
U0 means the system has detected a shortage of refrigerant. Daikin's manual also lists faulty refrigerant sensors as a cause, so it needs testing before anyone adds gas. A split system is sealed, so real low gas means a leak to find and fix. Refrigerant work must be done by an F-Gas certified engineer.
Why does my Daikin show A5?
A5 is a protection stop. In cooling, the indoor coil has dropped below 0°C and could freeze. In heating, it has gone above 65°C. Daikin's first checks are blocked airflow and dirty filters, so clean the filters and clear the space around the indoor unit. A5 clears by itself. If it keeps happening, book an engineer.
What does E7 mean on a Daikin?
E7 means the outdoor fan didn't start within 15 to 30 seconds of being told to. Look from a distance for leaves, snow or a cover stopping it, and clear it with the power off. If nothing is blocking it, the fan motor or outdoor board needs testing by an engineer.
How do I clear an error code on my Daikin?
Daikin's manual says that once the cause is fixed, pressing ON/OFF on the remote resets the code. Some codes need a power reset at the isolator, and some protection codes clear by themselves. If the cause is still there, the code comes back, so book an engineer rather than resetting again.
Why does my Daikin remote beep when I check codes?
Each press of Cancel sends a code to the indoor unit. A short beep or two short beeps mean that isn't the stored fault. A long continuous beep means the code on the remote's display is the one stored.
Will you repair a Daikin you didn't install?
Yes. We repair Daikin systems whoever fitted them. Tell us the code and the model number when you book, and the repair is priced in writing before any work starts.