LG air conditioner error codes: what the CH codes mean
When an LG wall or floor unit finds a fault, its display shows CH and a number one after the other, for example CH then 38. Here is how to read the code, what the common CH codes mean according to LG's own support pages, the checks LG says you can do yourself, and when to book an engineer.

- how an LG shows a fault
- CH + number
- LG's wait before power goes back on
- About 5 min
- repair price before any work
- Written
- we repair LG whoever fitted it
- Any fitter
On this page12 sections
How an LG shows an error code
On LG wall and floor units with a display, the code shows by itself: CH, then the number, repeating. CH then 05 means CH05.
- Three-digit codes show in steps, so CH, 2, 37 means CH237.
- Indicator lights instead of a display: LG says the first light blinks the units digit and the second the tens digit, so five blinks on the first light alone means CH05.
- A phone video makes counting easier.
- LG ThinQ app: open the Smart Diagnosis menu. LG says errors that stay after a restart appear there.
LG indoor unit and communication codes
Faults LG traces to the indoor unit, or to the link between the indoor and outdoor units.
| Code | What it means | What you can safely do | When to book |
|---|---|---|---|
| CH01 | Indoor room air sensor disconnected or shorted | Note the code and do one power reset | If it returns: the sensor needs testing |
| CH02 | Indoor pipe sensor (inlet) disconnected or shorted | Note the code and do one power reset | If it returns |
| CH05 | Indoor unit can't communicate with the outdoor unit | Check the breakers, including the outdoor unit's if it has its own, then one reset | If it returns, or straight after an install |
| CH06 | Indoor pipe sensor (outlet) disconnected or shorted | Note the code and do one power reset | If it returns |
| CH09 | Indoor unit memory (EEPROM) error | Note the code | Now: the indoor board needs checking |
| CH10 | Indoor fan motor has locked up | Switch off. Don't try to free the fan yourself | Now |
| CH12 | Indoor middle pipe sensor disconnected or shorted | Note the code and do one power reset | If it returns |
| CH53 | Outdoor unit can't communicate with the indoor unit | One power reset, waiting about 5 minutes | If it returns, or straight after an install |
| CH237, CH247 | Communication error because the outdoor unit has no power | Check the outdoor unit's breaker or isolator is on | If its power is on and the code stays |
LG outdoor unit, compressor and refrigerant codes
LG says these point to the outdoor unit, its compressor or its circuit board. Several need an F-Gas certified engineer.
| Code | What it means | What you can safely do | When to book |
|---|---|---|---|
| CH21 | DC peak or power module (IPM) fault: compressor DC voltage too high | Note the code and do one power reset | If it returns |
| CH22 | AC input current too high | Note the code and do one power reset | If it returns |
| CH23 | DC link voltage too low | One power reset | If it returns |
| CH25 | Supply voltage too low or too high | One power reset | If it keeps happening: the supply needs checking |
| CH26 | Inverter compressor has seized or isn't turning | Note the code and switch off | Now |
| CH27 | Short circuit fault detected | Switch off at the isolator | Now |
| CH28 | Inverter compressor DC voltage too high | Note the code | If it returns after one reset |
| CH29 | Inverter compressor current too high | Note the code | If it returns after one reset |
| CH32 | Compressor discharge pipe temperature too high. LG UK groups it with low refrigerant | Note the code | If it returns: an F-Gas engineer |
| CH38, CH33, CH36 | Low refrigerant, so the unit stops to protect itself | Switch off. Never top up or touch the pipes | Now, with an F-Gas engineer |
| CH60 | Outdoor circuit board memory (EEPROM) error | Note the code | Now |
| CH61 | Outdoor coil too hot in cooling. In heating, the indoor unit too hot, often a clogged filter | Clear around the outdoor unit or clean the filter, then a 3 minute power reset | If it returns after that |
| CH62 | Outdoor inverter board heat sink too hot | Clear space so air can flow freely around the outdoor unit | If it returns |
| CH63 | Outdoor coil pipe temperature too low | Note the code | If it returns |
| CH67 | Outdoor fan motor locked | From a distance, look for leaves or a cover stopping the fan | If the fan is clear |
LG outdoor sensor and installation codes
| Code | What it means | What you can safely do | When to book |
|---|---|---|---|
| CH41 | Compressor discharge pipe sensor disconnected or shorted | Note the code | Book a repair |
| CH44 | Outdoor air sensor disconnected or shorted | Note the code | Book a repair |
| CH45 | Outdoor coil middle sensor disconnected or shorted | Note the code | Book a repair |
| CH46 | Outdoor suction pipe sensor disconnected or shorted | Note the code | Book a repair |
| CH48 | Outdoor coil outlet (liquid pipe) sensor disconnected or shorted | Note the code | Book a repair |
| CH65 | Outdoor heat sink sensor disconnected or shorted | Note the code | Book a repair |
| CH66, CH90 to CH93 | Installation or test run problem: wiring, an unfinished test run or restricted refrigerant flow | Contact whoever installed it | If the installer can't help, we can |
Sources: LG help library, Single / Multi-Split Air Conditioner Error Codes chart, and LG UK's article on CH05, CH53, E0, CH32, CH33, CH36, CH38, CH66 and CH90 to CH93, checked October 2026.
CH05 and CH53: the units have stopped talking
LG says that where the outdoor unit has its own breaker, a tripped outdoor breaker causes CH05. If it has tripped, switch the indoor one off too, wait 3 minutes, then switch both back on together. If the outdoor breaker keeps tripping, leave it off and book an engineer.
Straight after an installation, LG says the installer should check the cables between the units. After normal use, it can be a temporary fault from an unstable power supply: switch off for about 5 minutes. If the code returns, it needs an engineer.
CH38: low refrigerant
LG says CH38 appears when the refrigerant level is low, and the unit stops to protect itself. A split system is sealed, so low refrigerant usually means a leak.
Topping up without finding the leak just lets it escape again. Refrigerant work must be done by an F-Gas certified engineer, who finds and fixes the leak before recharging the system.
CH61: the outdoor unit is too hot
In cooling, LG says CH61 shows when the outdoor unit's coil gets too hot, usually because hot air can't escape. Clear anything from the front, sides and back of the outdoor unit. If it sits in an enclosure or under a cover, make sure air can flow freely in and out.
In heating, LG says the usual cause is a dust-clogged indoor filter, so clean it. LG adds that CH61 doesn't clear by itself: switch off for 3 minutes, then back on. If it comes back after that, book an engineer. On some models the same fault shows as P4, P6 or P8.
Safe checks before you book
These are safe for anyone. If none help, or the same code keeps coming back, stop and book a visit.
- Write down the code and the model number from the label on the side of the indoor unit
- Check your consumer unit for a tripped breaker, for the outdoor unit too if it has its own
- Switch off, then clean the air filters behind the front panel, as your user manual shows
- Clear leaves, bins or covers from around the outdoor unit, keeping hands away from the fan
- Do one power reset: switch off at the breaker or isolator, wait about 5 minutes, then switch on
- If a breaker trips again, leave it off and book an engineer
Booking an LG repair
We repair LG wall, floor and multi-split systems whoever installed them. Tell us the code, the model number and when it started when you book, and we'll tell you what it usually means before the visit.
We confirm the cost of the visit when you book. On the visit, the engineer confirms the fault behind the code and gives you a written price for the repair before any work starts. Refrigerant work is done by our F-Gas and REFCOM certified engineers. Visits are booked ahead, not same day.
LG error code questions
What does CH05 mean on an LG air conditioner?
CH05 means the indoor unit can't communicate with the outdoor unit. LG says a tripped breaker for the outdoor unit causes it. Check the breakers, then do one power reset. If it happens straight after installation, the installer should check the cables between the units. If it returns, book an engineer.
What does CH38 mean on an LG air conditioner?
LG says CH38 means the refrigerant level is low, and the unit has stopped to protect itself. LG UK groups CH33 and CH36 with it. Low refrigerant usually means a leak, so book an F-Gas certified engineer to find and fix it.
What does CH10 mean on an LG?
LG's error code chart lists CH10 as the indoor fan motor locking up. Switch off and book an engineer. Don't try to turn the fan by hand or open the unit.
What does CH61 mean on an LG?
In cooling, the outdoor unit's coil has got too hot, usually because hot air can't escape. In heating, the indoor unit has got too hot, usually from a clogged filter. Clear around the outdoor unit or clean the filter, then switch off for 3 minutes. If it comes back, book an engineer.
How do I reset an LG air conditioner after an error?
Switch off at the plug, breaker or isolator, wait about 5 minutes as LG advises, then switch back on. If the cause has gone, the unit runs normally. Do it once: if the code comes back, it needs an engineer.
My LG has no display. How do I read the code?
Count the blinks. LG says the first indicator light blinks the units digit and the second blinks the tens digit. For example, five blinks on the first light and none on the second means CH05. If you're unsure, send us a short video when you book.