Fujitsu error codes: what they mean and what to do
When a Fujitsu wall unit finds a fault, the green Operation lamp and the orange Timer lamp blink in a set pattern. Each pattern stands for a code such as E:11 or E:97. Here is how to count them, what each code means according to Fujitsu's own service manual, what you can safely try and when to book a repair. The same applies to newer units sold as GENERAL.

- green Operation, orange Timer
- 2 lamps
- green then orange blinks: E:41
- 4 then 1
- repair price before any work
- Written
- we repair Fujitsu whoever fitted it
- Any fitter
On this page12 sections
How Fujitsu shows a fault
Fujitsu wall units don't show a code on a screen. Instead, the green Operation lamp blinks, then the orange Timer lamp blinks, and the pattern repeats.
- Two counts, two characters: four Operation blinks and one Timer blink, for example, is E:41, a room temperature sensor fault.
- Letters count as numbers: ten Operation blinks and one Timer blink is E:A1.
- Wired wall controller? The code shows on its screen instead, so you don't need to count.
- What Fujitsu advises: GENERAL, as Fujitsu now trades, tells owners to count the blinks of each lamp and contact a service agent.
- Its UK support pages also note that a lamp blinks during normal defrosting, so read the next section before you worry.
How to read the code from the lamps
Don't reset first
Count the pattern before you switch anything off. After a power reset, calling the stored code back up is an engineer's check.
Film it
Take a phone video of the indoor unit's lamps for at least two full cycles. It is much easier to count from a video than by eye.
Count the green lamp
Count the blinks of the green Operation lamp in one cycle. This is the first character of the code.
Count the orange lamp
Count the blinks of the orange Timer lamp that follow. This is the second character. Ten blinks means A.
Look it up
Match the two counts against the tables below, and write down the code and the model number from the label on the side of the indoor unit.
Blinking that isn't a fault
In heating, a Fujitsu indoor unit blinks a lamp slowly while it runs its automatic defrost, which clears ice from the outdoor unit in cold, damp weather.
- Defrost is normal: GENERAL's UK FAQ lists it as normal, and the unit carries on heating once it's done.
- A fault pattern is a set number of blinks that repeats, with the unit stopped or not heating or cooling.
- Not sure which you're seeing? Send us the video.
- Stored codes: Fujitsu's service manual says the unit keeps the most recent fault in memory, even through a power cut, and an engineer can call it back up after reconnecting.
- That check involves the indoor unit's buttons and test run mode, so leave it to us.
Communication and system codes
These codes mean the units, controllers or Wi-Fi adapter can't talk to each other properly, or don't suit each other.
| Code | Green, then orange | What Fujitsu says it means | What to do |
|---|---|---|---|
| E:11 | 1, then 1 | Serial communication error between indoor and outdoor units | One reset at the isolator. If it returns, book a repair: wiring or a circuit board needs checking. |
| E:12 | 1, then 2 | Wired remote controller communication error | Check the wall controller has power and a display. Book a repair if it continues. |
| E:18 | 1, then 8 | External communication error, including with the wireless LAN adapter | Check your router and Wi-Fi signal near the unit. Book a repair if the code stays. |
| E:22 | 2, then 2 | Indoor unit capacity error | Book a repair. It points to the combination of units, not something you can fix. |
| E:23 | 2, then 3 | Combination error between indoor and outdoor units | Book a repair. The units need checking against each other. |
Indoor unit codes
These come from the indoor unit's circuit board, buttons, sensors and fan.
| Code | Green, then orange | What Fujitsu says it means | What to do |
|---|---|---|---|
| E:32 | 3, then 2 | Indoor unit main circuit board error | Book a repair. |
| E:35 | 3, then 5 | MANUAL AUTO button error | Check nothing is pressing on the button on the indoor unit. Book a repair if it returns. |
| E:41 | 4, then 1 | Room temperature sensor error | Book a repair. The sensor or its connection needs testing. |
| E:42 | 4, then 2 | Indoor heat exchanger (coil) sensor error | Book a repair. The sensor or its connection needs testing. |
| E:51 | 5, then 1 | Indoor unit fan motor error | Book a repair. Don't try to turn the fan or reach inside the unit. |
Outdoor unit codes
Most of these are outdoor sensors, electronics or the compressor protecting itself. They all need an engineer, but a blocked outdoor unit is worth ruling out first.
| Code | Green, then orange | What Fujitsu says it means | What to do |
|---|---|---|---|
| E:62 | 6, then 2 | Outdoor unit main circuit board error | Book a repair. |
| E:64 | 6, then 4 | Power factor correction (PFC) circuit error | Book a repair. Leave the unit off. |
| E:65 | 6, then 5 | IPM error: the power module that drives the compressor | Book a repair. Leave the unit off. |
| E:71 | 7, then 1 | Discharge temperature sensor (thermistor) error | Book a repair. |
| E:73 | 7, then 3 | Outdoor coil liquid outlet sensor (thermistor) error | Book a repair. |
| E:74 | 7, then 4 | Outdoor air temperature sensor (thermistor) error | Book a repair. |
| E:84 | 8, then 4 | Current sensor error | Book a repair. |
| E:94 | 9, then 4 | Over current error | Book a repair. Don't keep restarting it. |
| E:95 | 9, then 5 | Compressor motor control error | Book a repair. Leave the unit off. |
| E:97 | 9, then 7 | Outdoor unit fan motor error | From a distance, check nothing is blocking the outdoor fan. If clear, book a repair. |
| E:99 | 9, then 9 | 4-way valve error: the valve that switches between heating and cooling | Book a repair. |
| E:A1 | 10, then 1 | Discharge temperature error: the compressor is running too hot | Clear space around the outdoor unit. Book a repair: Fujitsu lists low refrigerant among the causes. |
Source: Fujitsu General service manual SR_AS132EG_06 (KMCG wall units), error code table, checked October 2026. Lamp counts are for units with Operation and Timer lamps.
Outdoor fan and temperature codes: E:97 and E:A1
These two point to the outdoor unit. Check the space around it first, then book.
- E:97: the outdoor fan isn't reaching its speed. Fujitsu's manual lists a fan that is caught or locked, the fan motor and the main circuit board.
- From a safe distance, check for leaves, a cover, a bag or ice stopping the fan. Never put your hand or anything else into the fan guard. If it's clear, book a repair.
- E:A1: the compressor's discharge temperature has gone too high twice within 24 hours.
- Fujitsu's manual lists a closed valve, a blocked part in the refrigerant circuit, dirt on the outdoor coil, a failed sensor, a circuit board fault and insufficient refrigerant.
- Clear the space around the outdoor unit, then book a visit.
- If refrigerant is low, there is a leak, and finding it and recharging is work for an F-Gas certified engineer only.
Safe checks before you book
These are safe for anyone. If none help, or the same pattern comes back, stop there and book a visit.
- Film the lamps and write down the code and the model number from the label on the indoor unit
- Check the remote's batteries, the mode and any timers
- Switch off, then clean the air filters behind the front panel, as shown in your manual
- Clear leaves, bins or covers from around the outdoor unit, keeping hands away from the fan
- Check the drain pipe outside isn't blocked or squashed if the unit is dripping
- Do one power reset: switch off at the isolator or breaker, wait a few minutes, then switch back on
- Never open the indoor or outdoor unit, or touch wiring or refrigerant pipes
- If a breaker trips, water leaks or you smell burning, leave the unit off and book a repair
Booking a Fujitsu repair
We repair Fujitsu systems whoever installed them, including older units and ones that carry the GENERAL name. Send us the code or the lamp video, the model number and a photo of the label when you book a repair, and we'll tell you what it usually points to before we visit.
We confirm the cost of the visit when you book. On the visit the engineer confirms the fault behind the code and gives you a written price for the repair before any work starts. Visits are booked ahead at a time that suits you.
Fujitsu error code questions
Why are the lights flashing on my Fujitsu air conditioner?
If the green Operation lamp and the orange Timer lamp blink in a repeating pattern and the unit has stopped, it has found a fault. Count the blinks of each lamp to get the code. A single lamp blinking slowly while heating is usually the automatic defrost, which is normal.
What does E:11 mean on a Fujitsu?
E:11, one green blink then one orange blink, is a serial communication error: the indoor and outdoor units can't talk to each other. Try one power reset at the isolator. If it comes back, book a repair, as the connecting wiring or a circuit board needs checking.
What does E:51 mean on a Fujitsu?
E:51, five green blinks then one orange, is an indoor unit fan motor error. The fan inside the indoor unit isn't running as it should. Don't try to free it yourself or reach inside. Switch off and book a repair.
What does E:97 mean on a Fujitsu?
E:97, nine green blinks then seven orange, is an outdoor unit fan motor error. Fujitsu's manual lists a fan that is caught or locked, the fan motor or the circuit board. Check from a distance that nothing is blocking the outdoor fan, then book a repair if it's clear.
What does E:41 mean on a Fujitsu?
E:41, four green blinks then one orange, is a room temperature sensor error in the indoor unit. The unit can't read the room temperature, so it can't control heating or cooling. It needs an engineer to test the sensor and its connection.
My Fujitsu now says GENERAL. Are the codes the same?
Fujitsu General changed its trade name to GENERAL from 1 January 2026 and the ranges carry on, so recent units show codes the same way. Codes can still differ between ranges and model years, so send us the model number from the label and we'll check it against that unit's own manual.
Can I clear a Fujitsu error code myself?
You can switch the unit off at the isolator for a few minutes and back on once. That clears the stop, not the fault. If the pattern returns, book a repair. Recalling or erasing the stored code uses an engineer's procedure, so leave that to us.