What size air conditioner do you need?

Measure the room, tap a few answers, and see the unit size, what it costs to run and whether the outdoor unit passes the noise rule. It all works out on your phone as you type, and nothing is stored.

1. The room

m
m
m
What's the room used for?
Windows and sun
Insulation
Where is the room?

18 m² room, needs about 2.2 kW of cooling

A 2.5 kW unit, fitted from £1,850

Every system we fit heats as well, and its heating output is usually a little higher than the cooling rating.

Get a fixed price for this room

2. What it costs to run

h
days
15p to 19pan hour at full output (2.5 kW)
£26 to £34for those hours, averaging half output
5.8p to 7.5pper kWh of heat in winter

For comparison, a gas boiler gives heat for about 8.9p per kWh and any plug-in electric heater for 26.32p. Electricity at 26.32p and gas at 7.97p per kWh (Ofgem price cap, 1 October to 31 December 2026). We assume 3.5 to 4.5 units of cooling or heat for each unit of electricity, a cautious range: the energy labels on current units show more.

3. The noise check

For permitted development, the outdoor unit must come out at 37 dB(A) or lower 1 m outside every neighbouring window or door to a living room or bedroom (MCS 020(a)).

dB(A)
m
Surfaces within 1 m of the unit
Anything between the unit and the window?

36.5 dB(A): within the limit

Check every neighbouring window this way, on every side and floor: the loudest one decides. The 60 dB(A) to start with is the sound power Mitsubishi Electric lists for its 2.5 kW MUZ-LN25VG3; bigger units are usually louder, so use the figure on your unit's product sheet.

About the calculator

How is the size worked out?

From the floor area: Daikin's UK starting point is about 0.1 kW per square metre at a 2.4 m ceiling, and about a fifth more in the warmer South-East. Then it adds Daikin's allowances for large south or west windows, poor insulation, kitchens and each person beyond two, and our own allowances for glass extensions and loft rooms, which take the full sun. The survey measures it properly and settles the size.

Why not just buy a bigger unit to be safe?

An oversized unit costs more, cycles on and off, and is louder at its quietest. Daikin's 2.5 kW Perfera runs at 19 dB(A) on its quietest setting; the 5 kW model can't go below 27 dB(A). The right size is the quietest one that still copes on the hottest day.

How are the running costs worked out?

Electricity at 26.32p per kWh, the Ofgem price cap, 1 October to 31 December 2026. A split air conditioner moves heat rather than making it, so it gives several units of cooling or heat for each unit of electricity. We use 3.5 to 4.5, a cautious range; the energy labels on current units show more. Once the room is at temperature an inverter unit slows right down, so the yearly figure assumes half output on average. Standing charges are left out, because you pay them anyway.

Is it cheaper to heat a room with air conditioning than with gas?

Per unit of heat, yes at the current cap: about 5.8p to 7.5p per kWh, against about 8.9p from a gas boiler and 26.32p from any plug-in heater. For a whole house, gas central heating is still usually the practical choice, because it is already in every room.

What is the noise check?

The MCS 020(a) calculation every permitted development install must pass: the outdoor unit's sound power, the surfaces around it, the distance to each neighbouring window and any solid barrier give a level that must be 37 dB(A) or lower. We do the calculation for every window at the survey and give you a copy.

Where do I find my unit's sound power?

On the outdoor unit's product sheet, energy label or the MCS product database, listed as sound power level (LWA). It is a bigger number than the sound pressure figure, and the night or low-noise mode figure can't be used for the check.